Skip to main navigation Skip to search Skip to main content

Ultra-low level plutonium isotopes in the NIST SRM 4355A (Peruvian Soil-1)

  • Kenneth G.W. Inn
  • , Jerome LaRosa
  • , Svetlana Nour
  • , George Brooks
  • , Steve LaMont
  • , Rob Steiner
  • , Ross Williams
  • , Brad Patton
  • , Debbie Bostick
  • , Gregory Eiden
  • , Steve Petersen
  • , Matthew Douglas
  • , Donna Beals
  • , James Cadieux
  • , Greg Hall
  • , Steve Goldberg
  • , Stephan Vogt

Research output: Contribution to journal › Article › peer-review

4 Scopus citations

Abstract

For more than 20 years, countries and their agencies which monitor radionuclide discharge sites and storage facilities have relied on the National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 4355 Peruvian Soil. Its low fallout contamination makes it an ideal soil blank for measurements associated with terrestrial-pathway-to-man studies. Presently, SRM 4355 is out of stock, and a new batch of the Peruvian soil is currently under development as future NIST SRM 4355A. Both environmental radioanalytical laboratories and mass spectrometry communities will benefit from the use of this SRM. The former must assess their laboratory procedural contamination and measurement detection limits by measurement of blank sample material. The Peruvian Soil is so low in anthropogenic radionuclide content that it is a suitable virtual blank. On the other hand, mass spectrometric laboratories have high sensitivity instruments that are capable of quantitative isotopic measurements at low plutonium levels in the SRM 4355 (first Peruvian Soil SRM) that provided the mass spectrometric community with the calibration, quality control, and testing material needed for methods development and legal defensibility. The quantification of the ultra-low plutonium content in the SRM 4355A was a considerable challenge for the mass spectrometric laboratories. Careful blank control and correction, isobaric interferences, instrument stability, peak assessment, and detection assessment were necessary. Furthermore, a systematic statistical evaluation of the measurement results and considerable discussions with the mass spectroscopy metrologists were needed to derive the certified values and uncertainties. The one sided upper limit of the 95% tolerance with 95% confidence for the massic 239Pu content in SRM 4355A is estimated to be 54,000 atoms/g.

Original languageEnglish
Pages (from-to)667-671
Number of pages5
JournalApplied Radiation and Isotopes
Volume67
Issue number5
DOIs
StatePublished - May 2009
Externally publishedYes

Keywords

  • Analytical blank
  • Inductively-couple-plasma mass spectrometry
  • Plutonium
  • Radiochemistry
  • Reference material
  • Sediment
  • Thermal-ionization mass spectrometry

Fingerprint

Dive into the research topics of 'Ultra-low level plutonium isotopes in the NIST SRM 4355A (Peruvian Soil-1)'. Together they form a unique fingerprint.

Cite this