Skip to main navigation Skip to search Skip to main content

Trace xenon detection in helium environment via laser-induced breakdown spectroscopy

  • M. Burger
  • , L. Garrett
  • , A. J. Burak
  • , V. Petrov
  • , A. Manera
  • , P. Sabharwall
  • , X. Sun
  • , I. Jovanovic

Research output: Contribution to journal › Article › peer-review

37 Scopus citations

Abstract

There is significant motivation to develop and deploy novel nuclear reactor designs to deliver improved performance, safety, and economics for nuclear energy. In gas-cooled fast reactors that use helium as the primary coolant, the presence of xenon could indicate the onset of the fuel failure. We performed a feasibility study using single-pulse laser-induced breakdown spectroscopy to assess the sensitivity for trace xenon detection in a helium buffer of the pressure of 1.25 bar at room temperature. Under these experimental conditions, parametric optimization of recording parameters has ultimately led to the xenon detection limit of about 0.2 μmol mol-1 for 104 laser shots. The results show promise for the use of this technique for online monitoring of reactor fuel integrity, and motivate studies for the development of a compact measurement system that could be integrated with the reactor's primary helium-cooling loop.

Original languageEnglish
Pages (from-to)824-828
Number of pages5
JournalJournal of Analytical Atomic Spectrometry
Volume36
Issue number4
Early online dateApr 2021
DOIs
StatePublished - Apr 2021

Fingerprint

Dive into the research topics of 'Trace xenon detection in helium environment via laser-induced breakdown spectroscopy'. Together they form a unique fingerprint.

Cite this