The API 120 is a lightweight, portable neutron generator for active neutron interrogation (ANI) field work exploiting the associated particle technique. It incorporates a small sealed-tube accelerator, an all digital control system with smart on-board diagnostics, a simple platform-independent control interface and a comprehensive safety interlock philosophy with provisions for wireless control. The generator operates in a continuous output mode using either the D-D or D-T fusion reactions. To register the helium ion associated with fusion, the system incorporates a high resolution fiber optic imaging plate that may be coated with one of several different phosphors. The ion beam on the target measures less than 2 mm in diameter, thus making the system suitable for multi-dimensional imaging. The system is rated at 1E7 n/s for over 1000 h although higher yields are possible. The overall weight is 12 kg; power consumption is less than 50 W.
| Original language | English |
|---|---|
| Pages (from-to) | 753-758 |
| Number of pages | 6 |
| Journal | Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms |
| Volume | 241 |
| Issue number | 1-4 |
| DOIs | |
| State | Published - Dec 2005 |
| Externally published | Yes |
Keywords
- Active Neutron Interrogation (ANI)
- Associated Particle Imaging (API)
- Associated Particle Technique (APT)
- Deuterium Tritium Fusion
- Neutron Generator