Skip to main navigation Skip to search Skip to main content

Spectral performance of a composite single-crystal filtered thermal neutron beam for BNCT research at the University of Missouri

  • J. Brockman
  • , D. W. Nigg
  • , M. F. Hawthorne
  • , C. McKibben

Research output: Contribution to journal › Article › peer-review

14 Scopus citations

Abstract

Parameter studies, design calculations and initial neutronic performance measurements have been completed for a new thermal neutron beamline to be used for neutron capture therapy cell and small-animal radiobiology studies at the University of Missouri Research Reactor. The beamline features the use of single-crystal silicon and bismuth sections for neutron filtering and for reduction of incident gamma radiation. The calculated and measured thermal neutron fluxes produced at the irradiation location are 9.6×108 and 8.8×108 neutrons/cm2 s, respectively. Calculated and measured cadmium ratios (Au foils) are 217 and 132. These results indicate a well-thermalized neutron spectrum with sufficient thermal neutron flux for a variety of small animal BNCT studies.

Original languageEnglish
Pages (from-to)S222-S225
JournalApplied Radiation and Isotopes
Volume67
Issue number7-8 SUPPL.
DOIs
StatePublished - Jul 2009

Keywords

  • Activation
  • BNCT
  • Neutron source
  • Thermal

Fingerprint

Dive into the research topics of 'Spectral performance of a composite single-crystal filtered thermal neutron beam for BNCT research at the University of Missouri'. Together they form a unique fingerprint.

Cite this