TY - GEN
T1 - Sensitivity/Uncertainty Comparison Study Involving IRSN, LANL, and ORNL Tools to Support Validation
AU - Alwin, Jennifer
AU - Little, Robert
AU - Macquigg, Robbie
AU - Rising, Michael
AU - Leclaire, Nicolas
AU - Fernex, Frédéric
AU - Leal, Luiz
AU - Saylor, Ellen
AU - Clarity, Justin
AU - Marshall, B. J.
AU - Spencer, Kristina
N1 - Publisher Copyright:
© 2022 Proceedings of the Nuclear Criticality Safety Division Topical Meeting, NCSD 2022 - Embedded with the 2022 ANS Annual Meeting. All rights reserved.
PY - 2022
Y1 - 2022
N2 - Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods [1], three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize nuclear data from ENDF/B-VII.1 evaluation. This study examines five cases from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) [2] selected as application models: IEU-MET-FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM-004-001, MIX-COMP-THERM-001-001, and U233-SOL-THERM-001-001. This is a continuation of a previous study [3] to examine Pu and HEU cases: HEU-MET-FAST-013-001, HEU-SOL-THERM-001-008, PU-MET-FAST-022-001, and PU-SOL-THERM-001-001. Ultimately, comparison is made between Upper Subcritical Limits (USLs) obtained using each code package for each application case. Since differences exist in whether packages take into account margin of subcriticality (MOS), the USL is computed using only bias and bias uncertainty, also known as the calculational margin (CM) in ANSI/ANS-8.24 [4]. Results comparison appears to show that benchmark selection has a greater influence on the USL than the method used for calculation of bias and bias uncertainty.
AB - Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods [1], three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize nuclear data from ENDF/B-VII.1 evaluation. This study examines five cases from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) [2] selected as application models: IEU-MET-FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM-004-001, MIX-COMP-THERM-001-001, and U233-SOL-THERM-001-001. This is a continuation of a previous study [3] to examine Pu and HEU cases: HEU-MET-FAST-013-001, HEU-SOL-THERM-001-008, PU-MET-FAST-022-001, and PU-SOL-THERM-001-001. Ultimately, comparison is made between Upper Subcritical Limits (USLs) obtained using each code package for each application case. Since differences exist in whether packages take into account margin of subcriticality (MOS), the USL is computed using only bias and bias uncertainty, also known as the calculational margin (CM) in ANSI/ANS-8.24 [4]. Results comparison appears to show that benchmark selection has a greater influence on the USL than the method used for calculation of bias and bias uncertainty.
KW - analytical methods
KW - NCSP
KW - sensitivity/uncertainty
KW - transport
KW - validation
UR - https://www.scopus.com/pages/publications/85202565204
U2 - 10.13182/T126-37497
DO - 10.13182/T126-37497
M3 - Conference contribution
AN - SCOPUS:85202565204
T3 - Proceedings of the Nuclear Criticality Safety Division Topical Meeting, NCSD 2022 - Embedded with the 2022 ANS Annual Meeting
SP - 247
EP - 255
BT - Proceedings of the Nuclear Criticality Safety Division Topical Meeting, NCSD 2022 - Embedded with the 2022 ANS Annual Meeting
PB - American Nuclear Society
T2 - 2022 Nuclear Criticality Safety Division Topical Meeting, NCSD 2022
Y2 - 12 June 2022 through 16 June 2022
ER -