Skip to main navigation Skip to search Skip to main content

Sensitivity evaluation of the AGR 3-4 experiment thermal model irradiated in the Advanced Test Reactor

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

3 Scopus citations

Abstract

A temperature sensitivity evaluation has been performed on a thermal model for the AGR-3/4 fuel experiment on an individual capsule. The experiment was irradiated in the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). Four TRISO fuel irradiation experiments are planned for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program which supports the development of the Very High Temperature Gas-cooled Reactor under the Next-Generation Nuclear Plant project. AGR-3/4 is the third TRISO-particle fuel test of the four planned and is intended to test tri-structural-isotropic (TRISO)-coated, low-enriched uranium oxy-carbide fuel. The AGR-3/4 test was specifically designed to assess fission product transport through various graphite materials. The AGR-3/4 irradiation test in the AT R started in December 2011 and finished in April 2014. Forty-eight (48) TRISO-particle fueled compacts were inserted into 12 separate capsules for the experiment (four compacts per capsule). The purpose of this analysis was to assess the sensitivity of input variables for the capsule thermal model. A series of cases were compared to a base case by varying different input parameters into the ABAQUS finite element thermal model. These input parameters were varied by ±10% to show the temperature sensitivity to each parameter. The most sensitive parameter was the compact heat rates, followed by the outer control gap distance and neon gas fraction. Thermal conductivity of the compacts and thermal conductivity of the various graphite layers vary with fast neutron fluence and exhibited moderate sensitivity. The least sensitive parameters were the emissivities of the stainless steel and graphite, along with gamma heat rate in the non-fueled components. Separate sensitivity calculations were performed varying with fast neutron fluence, showing a general temperature rise with an increase in fast neutron fluence. This is a result of the control gas gap becoming larger due to the graphite shrinkage with neutron damage. A smaller sensitivity is due to the thermal conductivity of the fuel compacts with fast neutron fluence. Heat rates and fast neutron fluence were input from a detailed physics analysis using the Monte Carlo N-Particle (MCNP) code. Individual heat rates for each non-fuel component were input as well. A steady-state thermal analysis was performed for each sensitivity calculation. ATR outer shim control cylinders and neck shim rods along with driver fuel power and fuel depletion were incorporated into the physics heat rate calculations. Surface-to-surface radiation heat transfer along with conduction heat transfer through the gas mixture of helium-neon (used for temperature control) was used in the sensitivity calculations.

Original languageEnglish
Title of host publicationEnergy
PublisherAmerican Society of Mechanical Engineers (ASME)
ISBN (Electronic)9780791857441
DOIs
StatePublished - 2015
EventASME 2015 International Mechanical Engineering Congress and Exposition, IMECE 2015 - Houston, United States
Duration: Nov 13 2015Nov 19 2015

Publication series

NameASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE)
Volume6B-2015

Conference

ConferenceASME 2015 International Mechanical Engineering Congress and Exposition, IMECE 2015
Country/TerritoryUnited States
CityHouston
Period11/13/1511/19/15

Fingerprint

Dive into the research topics of 'Sensitivity evaluation of the AGR 3-4 experiment thermal model irradiated in the Advanced Test Reactor'. Together they form a unique fingerprint.

Cite this