TY - JOUR
T1 - Sensitivity and reliability of key electrochemical markers for detecting lithium plating during extreme fast charging
AU - Chinnam, Parameswara R.
AU - Tanim, Tanvir R.
AU - Dufek, Eric J.
AU - Dickerson, Charles C.
AU - Li, Meng
N1 - Funding Information:
Funding provided by the Vehicle Technologies Office of the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy under the guidance of the Advanced Battery Cell Research Program (eXtreme fast charge Cell Evaluation of Lithium-ion batteries – XCEL). This manuscript has been authored by Battelle Energy Alliance, LLC under Contract No. DE-AC07–05ID14517 for Idaho National Laboratory with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, worldwide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. The authors thank Samuel Gillard from the U.S. Department of Energy for supporting this project. The authors thank CAMP facility for providing graphite electrodes.
Funding Information:
Funding provided by the Vehicle Technologies Office of the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy under the guidance of the Advanced Battery Cell Research Program (eXtreme fast charge Cell Evaluation of Lithium-ion batteries – XCEL). This manuscript has been authored by Battelle Energy Alliance, LLC under Contract No. DE-AC07–05ID14517 for Idaho National Laboratory with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, worldwide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. The authors thank Samuel Gillard from the U.S. Department of Energy for supporting this project. The authors thank CAMP facility for providing graphite electrodes.
Publisher Copyright:
© 2021
PY - 2022/2
Y1 - 2022/2
N2 - Lithium plating is one of the key challenges for enabling extreme fast charging (XFC, ≤10 to 15 min charging at ≥6C) in graphite-based lithium-ion batteries. Significant R&D effort has been focused on how to mitigate Li plating. Parallel effort is also being devoted to developing methods to detect Li plating when and if it happens during fast charging. In that regard, electrochemical (EC) signature-based detection techniques are less resource intensive, more convenient, and more practical from an end-user application perspective. However, a comprehensive understanding of key plating related EC signatures for extreme fast charging is presently unavailable. In particular, there exist distinct issues of unreliability with key plating-related EC signatures—e.g., incremental capacity (dQ.dV−1), differential OCV (dOCV.dt−1), end of lithiation (EOL) rest voltage—at XFC conditions, and the underlying reasons have not been explored and identified methodically. Using a comprehensive test matrix and XFC conditions with Li/graphite half cells, this article highlights the unreliability issues associated with the EC Li plating diagnostics and explains the underlying root cause. This study finds distinct sensitivity and unreliability issues with plating related dQ.dV−1, dOCV.dt−1, and EOL rest voltage signatures with charging rates. The complex interaction between graphite and plated Li that happens through multiple competing mechanisms —Li stripping and chemical intercalation— at different charging rates is at the core of the sensitivity and unreliability issue.
AB - Lithium plating is one of the key challenges for enabling extreme fast charging (XFC, ≤10 to 15 min charging at ≥6C) in graphite-based lithium-ion batteries. Significant R&D effort has been focused on how to mitigate Li plating. Parallel effort is also being devoted to developing methods to detect Li plating when and if it happens during fast charging. In that regard, electrochemical (EC) signature-based detection techniques are less resource intensive, more convenient, and more practical from an end-user application perspective. However, a comprehensive understanding of key plating related EC signatures for extreme fast charging is presently unavailable. In particular, there exist distinct issues of unreliability with key plating-related EC signatures—e.g., incremental capacity (dQ.dV−1), differential OCV (dOCV.dt−1), end of lithiation (EOL) rest voltage—at XFC conditions, and the underlying reasons have not been explored and identified methodically. Using a comprehensive test matrix and XFC conditions with Li/graphite half cells, this article highlights the unreliability issues associated with the EC Li plating diagnostics and explains the underlying root cause. This study finds distinct sensitivity and unreliability issues with plating related dQ.dV−1, dOCV.dt−1, and EOL rest voltage signatures with charging rates. The complex interaction between graphite and plated Li that happens through multiple competing mechanisms —Li stripping and chemical intercalation— at different charging rates is at the core of the sensitivity and unreliability issue.
KW - Battery safety
KW - Electrochemical Li plating
KW - Extreme fast charging
KW - Lithium-ion battery
UR - https://www.scopus.com/pages/publications/85121267468
UR - https://www.mendeley.com/catalogue/8e1693b2-7ac5-3181-ac0c-f885dd95bc12/
U2 - 10.1016/j.est.2021.103782
DO - 10.1016/j.est.2021.103782
M3 - Article
AN - SCOPUS:85121267468
SN - 2352-152X
VL - 46
JO - Journal of Energy Storage
JF - Journal of Energy Storage
M1 - 103782
ER -