Abstract
The AP1000 power plant has implemented multiple layers of passive safety systems to enhance
reactor safety and ensure system integrity during postulated scenarios such as loss of coolant
accident (LOCA) and main steam line break (MSLB). Among these systems is the passive
containment cooling system (PCCS), which is designed to prevent the containment from exceeding
the design limits of pressure and temperature in case of a postulated design basis accident by
transferring decay heat from the containment vessel to the atmosphere. After 72 hours following the
initiation of large break (LBLOCA), the transfer of decay heat from the containment vessel to the
atmosphere is dependent upon air natural convection. This is due to the unavailability of the primary
heat removal mechanism represented by the condensate film from the Passive Containment Cooling
Water Storage Tank (PCCWST). Moreover, in the event of loss of shutdown decay heat removal
(LOSDHR), air natural convection serves as the sole mechanism for heat removal. Therefore, it is
essential to investigate the thermal hydraulics behavior of the containment under transient
conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT
model developed to analyze the effect of different parameters tuning, including air relative humidity,
air temperature, as well as steel containment temperature, on the natural convection capability to
remove the decay heat following LBLOCA. The model aims to examine the thermal behavior of the
containment and provides a comprehensive understanding of the system's natural convection
capability during postulated accidents. The simulation results can be used to improve the safety and
integrity of the containment system and provide valuable insights for future research in the field.
reactor safety and ensure system integrity during postulated scenarios such as loss of coolant
accident (LOCA) and main steam line break (MSLB). Among these systems is the passive
containment cooling system (PCCS), which is designed to prevent the containment from exceeding
the design limits of pressure and temperature in case of a postulated design basis accident by
transferring decay heat from the containment vessel to the atmosphere. After 72 hours following the
initiation of large break (LBLOCA), the transfer of decay heat from the containment vessel to the
atmosphere is dependent upon air natural convection. This is due to the unavailability of the primary
heat removal mechanism represented by the condensate film from the Passive Containment Cooling
Water Storage Tank (PCCWST). Moreover, in the event of loss of shutdown decay heat removal
(LOSDHR), air natural convection serves as the sole mechanism for heat removal. Therefore, it is
essential to investigate the thermal hydraulics behavior of the containment under transient
conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT
model developed to analyze the effect of different parameters tuning, including air relative humidity,
air temperature, as well as steel containment temperature, on the natural convection capability to
remove the decay heat following LBLOCA. The model aims to examine the thermal behavior of the
containment and provides a comprehensive understanding of the system's natural convection
capability during postulated accidents. The simulation results can be used to improve the safety and
integrity of the containment system and provide valuable insights for future research in the field.
| Original language | American English |
|---|---|
| Title of host publication | 2024 International Congress on Advances in Nuclear Power Plants (ICAPP) |
| DOIs | |
| State | Published - Jun 19 2024 |
Keywords
- Passive containment cooling system;
- CFD
- Natural circulation
- LOCA
- AP1000
INL Publication Number
- INL/CON-24-76468
- 169251
Fingerprint
Dive into the research topics of 'Sensitivity Analyses of Natural Convection in the AP1000 Passive Containment Cooling System Following LBLOCA Using CFD'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver