Abstract

In the present work, the similarity laws are derived from the non-dimensional conservation equations characterizing the DRACS system. A methodology is subsequently developed in applying these laws to specific components in the DRACS, as well as the primary and secondary loops. Based on this methodology, a reduced-scale experimental model has been designed for DRACS performance testing, which will be discussed in a companion paper [4].