N2 - This paper describes the use of a data-driven autoregressive integrated moving average model to predict body core temperature in humans during physical activity. We also propose a bootstrap technique to provide a measure of reliability of such predictions in the form of prediction intervals. We investigate the model's predictive capabilities and associated reliability using two distinct datasets, both obtained in the field under different environmental conditions. One dataset is used to develop the model, and the other one, containing an example of heat illness, is used to test the model. We demonstrate that accurate and reliable predictions of an extreme core temperature value of 39.5°C, can be made 20 minutes ahead of time, even when the predictive model is developed on a different individual having core temperatures within healthy physiological limits. This result suggests that data-driven models can be made portable across different core temperature levels and across different individuals. Also, we show that the bootstrap prediction intervals cover the actual core temperature, and that they exhibit intuitively expected behavior as a function of the prediction horizon and the core temperature variability.
AB - This paper describes the use of a data-driven autoregressive integrated moving average model to predict body core temperature in humans during physical activity. We also propose a bootstrap technique to provide a measure of reliability of such predictions in the form of prediction intervals. We investigate the model's predictive capabilities and associated reliability using two distinct datasets, both obtained in the field under different environmental conditions. One dataset is used to develop the model, and the other one, containing an example of heat illness, is used to test the model. We demonstrate that accurate and reliable predictions of an extreme core temperature value of 39.5°C, can be made 20 minutes ahead of time, even when the predictive model is developed on a different individual having core temperatures within healthy physiological limits. This result suggests that data-driven models can be made portable across different core temperature levels and across different individuals. Also, we show that the bootstrap prediction intervals cover the actual core temperature, and that they exhibit intuitively expected behavior as a function of the prediction horizon and the core temperature variability.
UR - https://www.scopus.com/pages/publications/57649193298
U2 - 10.1109/IEMBS.2007.4352348
DO - 10.1109/IEMBS.2007.4352348
M3 - Conference contribution
C2 - 18002014
AN - SCOPUS:57649193298
SN - 1424407885
SN - 9781424407880
T3 - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
SP - 545
EP - 548
BT - 29th Annual International Conference of IEEE-EMBS, Engineering in Medicine and Biology Society, EMBC'07
T2 - 29th Annual International Conference of IEEE-EMBS, Engineering in Medicine and Biology Society, EMBC'07
Y2 - 23 August 2007 through 26 August 2007
ER -