Skip to main navigation Skip to search Skip to main content

Pervaporation of water from aqueous HI using Nafion®-117 membranes for the sulfur-iodine thermochemical water splitting process

Research output: Contribution to journalArticlepeer-review

28 Scopus citations

Abstract

Nafion®-117 membranes have been successfully used to remove water from aqueous hydriodic acid (HI) by pervaporation. HI feeds were concentrated from approximately 1.7 to 5 M, and permeate concentrations ranged from 10 -3 to 10-4 M, regardless of the feed HI concentration. Temperatures examined were 22, 50, 70, and 100°C. Using 180 μm thick films, fluxes at 22°C were 0.43 kg/m2 h, and increased with increasing system temperature to a maximum of 1.5 kg/m2 h at 100°C. Durability studies over a period of 3 months operation revealed little membrane degradation and, in all cases, the membranes retained their bulk physical properties in that they remained flexible and plastic. More intensive thermomechanical testing revealed changes in the membrane morphology upon pervaporation of the HI feed at 100°C, however, these changes were not reflected in the observed water transport behavior.

Original languageEnglish
Pages (from-to)245-252
Number of pages8
JournalJournal of Membrane Science
Volume252
Issue number1-2
DOIs
StatePublished - Apr 15 2005

Keywords

  • Hydriodic acid
  • Liquid separation
  • Nafion membranes
  • Pervaporation
  • Sulfur-iodine process
  • Water separation

Fingerprint

Dive into the research topics of 'Pervaporation of water from aqueous HI using Nafion®-117 membranes for the sulfur-iodine thermochemical water splitting process'. Together they form a unique fingerprint.