Abstract
The Advanced Test Reactor (ATR) is a light water reactor with aluminum clad driver fuel. Strict
limits are implemented on pH, conductivity, and filterable solids concentration to assure the performance of
the driver fuel and limit corrosion of the primary coolant system (PCS) pressure boundary components. A bypass
demineralizer system is used to maintain PCS coolant within allowable bands for each of the aforementioned
variables. Unlike many other reactors, the ATR does
not have a filtration system. As such, failure of ion exchange resin in the bypass demineralizer can
defeat the purpose of the system and result in high filterable solids in the PCS. Power operation with
high filterable solids is prohibited by a safety analysis report commitment. This paper discusses
recent failures of the ATR bypass demineralizer system. The testing and analysis done to deduce the
cause of the failures is covered, as well as short term mitigative steps that were taken. To prevent
the likelihood of future issues, historical data from the ATR and industry is used to develop a reliability model
of the ATR bypass demineralizer system. Evidence of degradation due to high temperatures and accumulated dose
was found in the cause investigation. As such, special attention
is given to ion exchange resin failure due to these variables. The reliability model is used to develop
a resin service life limit and inform the ATR testing and maintenance program.
limits are implemented on pH, conductivity, and filterable solids concentration to assure the performance of
the driver fuel and limit corrosion of the primary coolant system (PCS) pressure boundary components. A bypass
demineralizer system is used to maintain PCS coolant within allowable bands for each of the aforementioned
variables. Unlike many other reactors, the ATR does
not have a filtration system. As such, failure of ion exchange resin in the bypass demineralizer can
defeat the purpose of the system and result in high filterable solids in the PCS. Power operation with
high filterable solids is prohibited by a safety analysis report commitment. This paper discusses
recent failures of the ATR bypass demineralizer system. The testing and analysis done to deduce the
cause of the failures is covered, as well as short term mitigative steps that were taken. To prevent
the likelihood of future issues, historical data from the ATR and industry is used to develop a reliability model
of the ATR bypass demineralizer system. Evidence of degradation due to high temperatures and accumulated dose
was found in the cause investigation. As such, special attention
is given to ion exchange resin failure due to these variables. The reliability model is used to develop
a resin service life limit and inform the ATR testing and maintenance program.
| Original language | American English |
|---|---|
| DOIs | |
| State | Published - Jun 15 2025 |
| Event | 19th International Conference on Probabilistic Safety Assessment and Analysis - Chicago, United States Duration: Jun 15 2025 → Jun 18 2025 |
Conference
| Conference | 19th International Conference on Probabilistic Safety Assessment and Analysis |
|---|---|
| Abbreviated title | PSA 2025 |
| Country/Territory | United States |
| City | Chicago |
| Period | 06/15/25 → 06/18/25 |
INL Publication Number
- INL/CON-24-80777
- 191477
Fingerprint
Dive into the research topics of 'Operational Experience and Development of a Reliability Model for the Advanced Test Reactor Demineralizer System'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver