Li-ion batteries, when charged at fast-charging rates (>2C), suffer from reduced lifetimes and can undergo catastrophic failure. During high-rate charging, Li-ions are unable to rapidly transport through high-loading electrodes (>4 mAh cm−2). This results in unequal charge distributions, potentials, and utilization of the active material, which can lead to Li plating. Li-ion concentration polarization, in which Li-ions deplete in the anode and accumulate in the cathode during charging, precedes Li plating. An operando FTIR-ATR graphite/NMC cell developed in this research captured Li-ion concentration polarization in real-time. During fast charging, decreases in Li-ion concentration (>95%) were measured at the back of the anode. This is the first verification of complete Li-ion depletion within the anode at high C-rates. The measurements also showed graphite stage transition. A P2D model was developed for comparison to the operando measurements. The measurements agreed with the model in some cases, but disparities existed at high C-rates and loadings. In the experiment, the Li-ion concentration often failed to recover to 1.2 M until several hours after charging, whereas the model Li-ion concentration rapidly recovered. The contrast between the model and experiment results indicates that further investigation is required to improve understanding of Li-ion concentration dynamics during fast charging.
| Original language | English |
|---|---|
| Article number | 238058 |
| Journal | Journal of Power Sources |
| Volume | 656 |
| Early online date | Aug 14 2025 |
| DOIs | |
| State | Published - Nov 15 2025 |
Keywords
- Electrolyte
- Fast charging
- FTIR
- Li-ion
- Operando
- P2D
INL Publication Number
- INL/JOU-25-87504
- 206440
Fingerprint
Dive into the research topics of 'Operando FTIR investigation of salt dynamics in Li-ion batteries during fast charging'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver