Skip to main navigation Skip to search Skip to main content

Micro-Pocket Fission Detectors (MPFDs) for in-core neutron detection

Research output: Contribution to journalArticlepeer-review

16 Scopus citations

Abstract

Neutron sensors capable of real-time measurement of neutrons in high-flux environments are necessary for tests aimed at demonstrating the performance of experimental nuclear reactor fuels and materials in material test reactors (MTRs). In-core Micro-Pocket Fission Detectors (MPFDs) have been studied at Kansas State University for many years. Previous MPFD prototypes were successfully built and tested with promising results. Efforts are now underway to develop advanced MPFDs with radiation-resistant, high-temperature materials capable of withstanding irradiation test conditions in high performance material and test reactors. Stackable MPFDs have been designed, built, and successfully demonstrated as in-core neutron sensors. Advances in the electrodeposition and measurement of neutron reactive material, along with refinements to composition optimization simulations, have enhanced the capabilities of contemporary MPFDs.

Original languageEnglish
Article number4703
Pages (from-to)318-323
Number of pages6
JournalAnnals of Nuclear Energy
Volume87
DOIs
StatePublished - Jan 1 2016

Keywords

  • Fission chamber
  • Micro-Pocket Fission Detectors
  • Neutron detector
  • Reactor instrumentation

Fingerprint

Dive into the research topics of 'Micro-Pocket Fission Detectors (MPFDs) for in-core neutron detection'. Together they form a unique fingerprint.

Cite this