Skip to main navigation Skip to search Skip to main content

Metrics of medical image quality: Task-based model observers vs. image discrimination/perceptual difference models

Research output: Contribution to journalConference articlepeer-review

3 Scopus citations

Abstract

There have been two distinct approaches to develop human vision models that can be used to perform automated evaluation and optimization of medical image quality: linear task based model observers vs. perceptual difference/image discrimination models. Although these two approaches are very different there has been little work directly comparing them in their ability to optimize human performance in clinically relevant tasks. We compared the effectiveness of these two types of metrics of image quality to perform automated computer optimization of JPEG 2000 image compression encoder settings using test images that combined real x-ray coronary angiogram backgrounds with simulated filling defects of 184 different size/shapes. A genetic algorithm was used to optimize the JPEG 2000 encoder settings with respect to: a) a particular task based model observer performance (non-prewhitening matched filter with an eye filter, NPWE; b) a particular perceptual difference/image discrimination model error metric (DCTune2.0; NASA Ames Research Center). A subsequent human psychophysical study was conducted to evaluate the effect of the two different optimized compression encoder settings on visual detection of the simulated filling defect in one of four locations (four alternative forced choice; 4 AFC). Results show that optimizing JPEG 2000 encoder settings with respect to both the NPWE performance and DCTune 2.0 perceptual error lead to improved human task performance relative to human performance with the default encoder settings. However, the NPWE-optimization led to much greater human performance improvement than the perceptual difference model optimization.

Original languageEnglish
Article number04
Pages (from-to)42-52
Number of pages11
JournalProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume5
Issue number26
DOIs
StatePublished - 2004
Externally publishedYes
EventMedical Imaging 2004 - Image Perception, Observer Performance, and Technology Assessment - San Diego, CA, United States
Duration: Feb 17 2004Feb 19 2004

Keywords

  • Computer automated evaluation
  • Human performance
  • Image compression
  • Image discrimination
  • JPEG 2000
  • Metrics of image quality
  • Model observers
  • Perceptual difference
  • Visual detection

Fingerprint

Dive into the research topics of 'Metrics of medical image quality: Task-based model observers vs. image discrimination/perceptual difference models'. Together they form a unique fingerprint.

Cite this