The authors would like to acknowledge partial support for this project from (i) the Idaho Water Resources Research Institute and the USGS 104b program, (ii) the National Science Foundation under award number EAR1559348, and (iii) the Grant 19-028-300 California State Water Resources Control Board. Daniele Tonina also acknowledges support from Agricultural Experiment Station with funding from the Hatch Act (Accession Number IDA01722) through the USDA National Institute of Food and Agriculture. Equipment used for experiments was supported by the National Science Foundation (NSF Grant 2043382). Any opinions, conclusions, or recommendations expressed in this article are those of the authors and do not necessarily reflect the views of the supporting agencies.
Publisher Copyright:
© 2023 The Author(s). Published by IOP Publishing Ltd.
PY - 2023/12
Y1 - 2023/12
N2 - Porous media flows are common in both natural and anthropogenic systems. Mapping these flows in a laboratory setting is challenging and often requires non-intrusive measurement techniques, such as particle image velocimetry (PIV) coupled with refractive index matching (RIM). RIM-coupled PIV allows the mapping of velocity fields around transparent solids by analyzing the movement of neutrally buoyant micron-sized seeding particles. The use of this technique in a porous medium can be problematic because seeding particles adhere to grains, which causes the grain bed to lose transparency and can obstruct pore flows. Another non-intrusive optical technique, planar laser-induced fluorescence (PLIF), can be paired with RIM and does not have this limitation because fluorescent dye is used instead of particles, but it has been chiefly used for qualitative flow visualization. Here, we propose a quantitative PLIF-based methodology to map both porous media flow fields and porous media architecture. Velocity fields are obtained by tracking the advection-dominated movement of the fluorescent dye plume front within a porous medium. We also propose an automatic tracking algorithm that quantifies 2D velocity components as the plume moves through space in both an Eulerian and a Lagrangian framework. We apply this algorithm to three data sets: a synthetic data set and two laboratory experiments. Performance of this algorithm is reported by the mean (bias error, B) and standard deviation (random error, SD) of the residuals between its results and the reference data. For the synthetic data, the algorithm produces maximum errors of B & SD = 32% & 23% in the Eulerian framework, respectively, and B & SD = −0.04% & 3.9% in the Lagrangian framework. The small-scale laboratory experimental data requires the Eulerian framework and produce errors of B & SD = −0.5% & 33%. The Lagrangian framework is used on the large-scale laboratory experimental data and produces errors of B & SD = 5% & 44%. Mapping the porous media architecture shows negligible error for reconstructing calibration grains of known dimensions.
AB - Porous media flows are common in both natural and anthropogenic systems. Mapping these flows in a laboratory setting is challenging and often requires non-intrusive measurement techniques, such as particle image velocimetry (PIV) coupled with refractive index matching (RIM). RIM-coupled PIV allows the mapping of velocity fields around transparent solids by analyzing the movement of neutrally buoyant micron-sized seeding particles. The use of this technique in a porous medium can be problematic because seeding particles adhere to grains, which causes the grain bed to lose transparency and can obstruct pore flows. Another non-intrusive optical technique, planar laser-induced fluorescence (PLIF), can be paired with RIM and does not have this limitation because fluorescent dye is used instead of particles, but it has been chiefly used for qualitative flow visualization. Here, we propose a quantitative PLIF-based methodology to map both porous media flow fields and porous media architecture. Velocity fields are obtained by tracking the advection-dominated movement of the fluorescent dye plume front within a porous medium. We also propose an automatic tracking algorithm that quantifies 2D velocity components as the plume moves through space in both an Eulerian and a Lagrangian framework. We apply this algorithm to three data sets: a synthetic data set and two laboratory experiments. Performance of this algorithm is reported by the mean (bias error, B) and standard deviation (random error, SD) of the residuals between its results and the reference data. For the synthetic data, the algorithm produces maximum errors of B & SD = 32% & 23% in the Eulerian framework, respectively, and B & SD = −0.04% & 3.9% in the Lagrangian framework. The small-scale laboratory experimental data requires the Eulerian framework and produce errors of B & SD = −0.5% & 33%. The Lagrangian framework is used on the large-scale laboratory experimental data and produces errors of B & SD = 5% & 44%. Mapping the porous media architecture shows negligible error for reconstructing calibration grains of known dimensions.
KW - Salmon redd
KW - hyporheic zone
KW - planar laser-induced fluorescence
KW - porous media architecture
KW - porous media flow
KW - refractive index matching
UR - https://www.scopus.com/pages/publications/85174397286
UR - https://www.mendeley.com/catalogue/e5f19e40-12eb-3f87-99dc-8ea2b07581b5/
U2 - 10.1088/1361-6501/acfb2b
DO - 10.1088/1361-6501/acfb2b
M3 - Article
AN - SCOPUS:85174397286
SN - 0957-0233
VL - 34
JO - Measurement Science and Technology
JF - Measurement Science and Technology
IS - 12
M1 - 125805
ER -