Measurement of tritium permeation in flibe (2LiF-BeF2)

Research output: Contribution to journalArticlepeer-review

60 Scopus citations

Abstract

This paper reports on the experimental investigation of tritium permeation in flibe (2LiF-BeF2) at the Safety and Tritium Applied Research facility of the Idaho National Laboratory. A stainless steel cell formed by two independent volumes separated by a 2-mm thick nickel membrane is maintained at temperatures between 500 and 700 °C. A controlled amount of T2 gas is flown in excess of argon in the source volume in contact with the bottom side of the nickel membrane, while a layer of molten salt is in contact with the top side. The tritium permeating above the liquid surface is carried by an argon flow to a diagnostic system comprised of a quadrupole mass spectrometer, a gas chromatographer and a proportional counter. Tritium permeability in flibe as a function of temperature is determined by the measured permeation flow rates reached in steady-state conditions, while the diffusivity is determined by fitting the transient process with the analytical solution for the diffusion process. As a result, the solubility of tritium in flibe as a function of temperature is also determined.

Original languageEnglish
Pages (from-to)1331-1334
Number of pages4
JournalFusion Engineering and Design
Volume83
Issue number7-9
DOIs
StatePublished - Dec 2008

Keywords

  • Diffusivity
  • Fusion
  • Molten salt
  • Solubility
  • Tritium

Fingerprint

Dive into the research topics of 'Measurement of tritium permeation in flibe (2LiF-BeF2)'. Together they form a unique fingerprint.

Cite this