Skip to main navigation Skip to search Skip to main content

Lifetime-predictions of a glass-ceramic with machined flaws

  • T. Gent
  • , D. Tucker

Research output: Contribution to journal › Article › peer-review

2 Scopus citations

Abstract

A dynamic fatigue study was performed on a Li2O-Al2O3-SiO2 glass ceramic to assess its susceptibility to delayed failure and to compare the results with those from a previous study. Fracture mechanics techniques were used to analyse the results for the purpose of making lifetime predictions. The material strength and lifetime was seen to increase due to the removal of residual stress through grinding and polishing. Influence on time-to-failure is addressed for the case with and without residual stress present.

Original languageEnglish
Pages (from-to)1535-1538
Number of pages4
JournalJournal of Materials Science
Volume30
Issue number6
DOIs
StatePublished - Jan 1995

Fingerprint

Dive into the research topics of 'Lifetime-predictions of a glass-ceramic with machined flaws'. Together they form a unique fingerprint.

Cite this