Skip to main navigation Skip to search Skip to main content

Interlaboratory round robin study on axial tensile properties of SiC-SiC CMC tubular test specimens

  • Gyanender Singh
  • , Steve Gonczy
  • , Christian Deck
  • , Edgar Lara-Curzio
  • , Yutai Katoh

Research output: Contribution to journal › Article › peer-review

33 Scopus citations

Abstract

An interlaboratory round robin study was conducted on the tensile strength of SiC-SiC ceramic matrix composite (CMC) tubular test specimens at room temperature with the objective of expanding the database of mechanical properties of nuclear grade SiC-SiC and establishing the precision and bias statement for standard test method ASTM C1773. The mechanical properties statistics from the round robin study and the precision statistics and precision statement are presented herein. The data show reasonable consistency across the laboratories, indicating that the current C1773-13 ASTM standard is adequate for testing ceramic fiber reinforced ceramic matrix composite tubular test specimen. It was found that the distribution of ultimate tensile strength data was best described with a two-parameter Weibull distribution, while a lognormal distribution provided a good description of the distribution of proportional limit stress data.

Original languageEnglish
Pages (from-to)1334-1349
Number of pages16
JournalInternational Journal of Applied Ceramic Technology
Volume15
Issue number6
DOIs
StatePublished - Nov 1 2018

Keywords

  • SiC
  • axial
  • ceramic matrix composite
  • cladding
  • nuclear
  • precision and bias
  • round robin
  • tensile

Fingerprint

Dive into the research topics of 'Interlaboratory round robin study on axial tensile properties of SiC-SiC CMC tubular test specimens'. Together they form a unique fingerprint.

Cite this