Skip to main navigation Skip to search Skip to main content

High-temperature safety testing of irradiated AGR-1 TRISO fuel

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

2 Scopus citations

Abstract

Three irradiated AGR-1 UCO TRISO fuel compacts were tested using a time-varying temperature profile with a peak temperature of 1695 °C, simulating a conduction cooldown event in a gas-cooled reactor. Of the approximately 12,378 fuel particles in this test, less than a single particle's inventory of Cs, Eu, Kr or Sr was released during the test, indicating that all TRISO layers in all particles remained intact. The transient nature of the test did not stress the fuel beyond what has been observed in isothermal tests within the same temperature range. It is anticipated that tests of this nature will be repeated using fuel from subsequent irradiations (e.g. AGR-2, which has both UCO and UO2 fuel compacts, and AGR-5/6/7, which has only UCO fuel).

Original languageEnglish
Title of host publicationInternational Topical Meeting on High Temperature Reactor Technology, HTR 2016
PublisherAmerican Nuclear Society
Pages520-527
Number of pages8
ISBN (Electronic)9780894487323
StatePublished - 2016
Event8th International Topical Meeting on High Temperature Reactor Technology, HTR 2016 - Las Vegas, United States
Duration: Nov 6 2016 → Nov 10 2016

Publication series

NameInternational Topical Meeting on High Temperature Reactor Technology, HTR 2016

Conference

Conference8th International Topical Meeting on High Temperature Reactor Technology, HTR 2016
Country/TerritoryUnited States
CityLas Vegas
Period11/6/16 → 11/10/16

Fingerprint

Dive into the research topics of 'High-temperature safety testing of irradiated AGR-1 TRISO fuel'. Together they form a unique fingerprint.

Cite this