N2 - The U.S. grid is rapidly transitioning towards uti-lizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint. Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high pen-etration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter-based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL's Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.
AB - The U.S. grid is rapidly transitioning towards uti-lizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint. Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high pen-etration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter-based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL's Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.
KW - Battery Energy Storage Systems (BESS)
KW - Grid Stability
KW - High-Penetration (HP)
KW - Microgrid
KW - frequency-Watt Controls
UR - https://www.scopus.com/pages/publications/85193465991
UR - https://www.mendeley.com/catalogue/f8c2cb98-aa4f-35aa-b739-64d21a3e1c8a/
U2 - 10.1109/GreenTech58819.2024.10520610
DO - 10.1109/GreenTech58819.2024.10520610
M3 - Conference contribution
AN - SCOPUS:85193465991
SN - 9798350308587
T3 - IEEE Green Technologies Conference
SP - 22
EP - 25
BT - 2024 IEEE Green Technologies Conference, GreenTech 2024
PB - IEEE Computer Society
T2 - 2024 IEEE Green Technologies Conference, GreenTech 2024
Y2 - 3 April 2024 through 5 April 2024
ER -