Abstract
This paper focuses on the understanding and evaluation of the hydrodynamic and heat transfer phenomena of the axial thermal steady-state behavior of localized, heated gas-jet impingement on an adjacent heated rod in stagnant air and stagnant water conditions. The tests are performed under model (not prototypical) conditions, using argon as the injection gas due to its similar monatomic properties and specific heat ratio to xenon, which is the most abundant fission gas product. Stagnant coolant environments (air and water) are representative of accident scenarios of a dry core (simulated LOCA) and a prolonged pump failure (simulated ULOF). The parameters investigated are the heater rod power (q_rod), gas-jet Reynolds number (Re_j), and the gas-jet temperature (T_j).
| Original language | English |
|---|---|
| Pages (from-to) | 836-839 |
| Number of pages | 4 |
| Journal | Transactions of the American Nuclear Society |
| Volume | 134 |
| Early online date | May 31 2026 |
| DOIs | |
| State | Published - May 31 2026 |
| Event | ANS Annual Conference, 2026 - Denver, United States Duration: May 31 2026 → Jun 3 2026 |
INL Publication Number
- INL/CON-26-89758
- 211715
Fingerprint
Dive into the research topics of 'Experimental Study of Dry and Submerged Heated Rod Subjected to Gas-Jet Impingement'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver