Abstract
An experiment was conducted to show that during one-sided heating, as in ITER, a copper divertor plate with the proper side wall thickness, at low system pressure and velocity can absorb without failing an incident heat flux, qi, that significantly exceed the value, qiCHF which is associated with local CHF at the wall of the coolant channel. The experiment was performed using a 30 kW electron beam test system for heating of a square cross-section divertor heat sink with a smooth circular channel of 7.6 mm diameter. The heated width, length, and wall thickness were 16, 40, and 3 mm.
| Original language | English |
|---|---|
| Pages | 206-209 |
| Number of pages | 4 |
| State | Published - 1995 |
| Externally published | Yes |
| Event | Proceedings of the 1995 16th IEEE/NPSS Symposium on Fusion Engineering. Part 1 (of 2) - Champaign, IL, USA Duration: Oct 1 1995 → Oct 5 1995 |
Conference
| Conference | Proceedings of the 1995 16th IEEE/NPSS Symposium on Fusion Engineering. Part 1 (of 2) |
|---|---|
| City | Champaign, IL, USA |
| Period | 10/1/95 → 10/5/95 |
Fingerprint
Dive into the research topics of 'Experimental investigation of the post-CHF enhancement factor for a prototypical ITER divertor plate with water coolant'. Together they form a unique fingerprint.Cite this