Skip to main navigation Skip to search Skip to main content

Experimental investigation of the post-CHF enhancement factor for a prototypical ITER divertor plate with water coolant

  • T. D. Marshall
  • , R. D. Watson
  • , J. M. McDonald
  • , D. L. Youchison

Research output: Contribution to conference › Paper › peer-review

11 Scopus citations

Abstract

An experiment was conducted to show that during one-sided heating, as in ITER, a copper divertor plate with the proper side wall thickness, at low system pressure and velocity can absorb without failing an incident heat flux, qi, that significantly exceed the value, qiCHF which is associated with local CHF at the wall of the coolant channel. The experiment was performed using a 30 kW electron beam test system for heating of a square cross-section divertor heat sink with a smooth circular channel of 7.6 mm diameter. The heated width, length, and wall thickness were 16, 40, and 3 mm.

Original languageEnglish
Pages206-209
Number of pages4
StatePublished - 1995
Externally publishedYes
EventProceedings of the 1995 16th IEEE/NPSS Symposium on Fusion Engineering. Part 1 (of 2) - Champaign, IL, USA
Duration: Oct 1 1995 → Oct 5 1995

Conference

ConferenceProceedings of the 1995 16th IEEE/NPSS Symposium on Fusion Engineering. Part 1 (of 2)
CityChampaign, IL, USA
Period10/1/95 → 10/5/95

Fingerprint

Dive into the research topics of 'Experimental investigation of the post-CHF enhancement factor for a prototypical ITER divertor plate with water coolant'. Together they form a unique fingerprint.

Cite this