TY - JOUR
T1 - Evaluation of the spatial self-shielding impact for TRISO-based nuclear fuel depletion
AU - Martin, Nicolas
AU - Youinou, Gilles
N1 - Funding Information:
This research was funded by the U.S. Department of Energy Advanced Reactor Technologies Program for Gas Cooled Reactors and made use of the resources of the High Performance Computing Center at Idaho National Laboratory, which is supported by the Office of Nuclear Energy of the U.S. Department of Energy and the Nuclear Science User Facilities under contract no. DE-AC07-05ID14517.
Funding Information:
The authors would like to thank Alexandria Madden for performing a technical editing of the manuscript. This manuscript was authored by Battelle Energy Alliance, LLC under contract no. DE-AC07-05ID14517 with the U.S. Department of Energy. The U.S. Government retains and the publisher, by accepting the article for publication, acknowledges that the U.S. Government retains a nonexclusive, paid-up, irrevocable, worldwide license to publish or reproduce the published form of this manuscript, or allow others to do so, for U.S. Government purposes. This research was funded by the U.S. Department of Energy Advanced Reactor Technologies Program for Gas Cooled Reactors and made use of the resources of the High Performance Computing Center at Idaho National Laboratory, which is supported by the Office of Nuclear Energy of the U.S. Department of Energy and the Nuclear Science User Facilities under contract no. DE-AC07-05ID14517.
Publisher Copyright:
© 2023 Elsevier B.V.
PY - 2024/1
Y1 - 2024/1
N2 - Reactor physics analyses of nuclear cores with nuclear fuel concepts containing tristructural isotropic (TRISO) particles, such as pebbles or compact fuel elements, rely on various degrees of simplification to keep these highly heterogeneous problems computationally tractable. One such limitation regards the level of spatial discretization employed during burnup calculations, where traditionally only a limited number of spatial zones are modeled at the full core level and assume that the spectrum is constant within the fuel elements and TRISO particles in this depletion zone. This type of assumption neglects the impact of spatial self-shielding effect within the kernels (microscale level) as well as within the compact or pebbles (mesoscale level). The Monte Carlo code Serpent 2 contains many relevant features for efficiently modeling this type of geometry, including a collision-based domain decomposition intended for very large burnup calculations, which we leveraged for this work to quantify the impact of capturing neutron flux variations occurring at the micro- and mesoscale level on a series of high-temperature gas-cooled reactor fuel element depletion problems. While spatial self-shielding is observed at both scales, with differences from a volume-averaged burnup of ±7% within the kernels and ±2% between TRISO particles within the fuel element, the conjugated effect on nuclide inventories and multiplication factor are negligible, hence confirming that assuming a single average spectrum value may be sufficient for most applications.
AB - Reactor physics analyses of nuclear cores with nuclear fuel concepts containing tristructural isotropic (TRISO) particles, such as pebbles or compact fuel elements, rely on various degrees of simplification to keep these highly heterogeneous problems computationally tractable. One such limitation regards the level of spatial discretization employed during burnup calculations, where traditionally only a limited number of spatial zones are modeled at the full core level and assume that the spectrum is constant within the fuel elements and TRISO particles in this depletion zone. This type of assumption neglects the impact of spatial self-shielding effect within the kernels (microscale level) as well as within the compact or pebbles (mesoscale level). The Monte Carlo code Serpent 2 contains many relevant features for efficiently modeling this type of geometry, including a collision-based domain decomposition intended for very large burnup calculations, which we leveraged for this work to quantify the impact of capturing neutron flux variations occurring at the micro- and mesoscale level on a series of high-temperature gas-cooled reactor fuel element depletion problems. While spatial self-shielding is observed at both scales, with differences from a volume-averaged burnup of ±7% within the kernels and ±2% between TRISO particles within the fuel element, the conjugated effect on nuclide inventories and multiplication factor are negligible, hence confirming that assuming a single average spectrum value may be sufficient for most applications.
KW - Depletion
KW - Spatial self-shielding
KW - TRISO
UR - https://www.scopus.com/pages/publications/85177237816
U2 - 10.1016/j.nucengdes.2023.112749
DO - 10.1016/j.nucengdes.2023.112749
M3 - Article
AN - SCOPUS:85177237816
SN - 0029-5493
VL - 416
JO - Nuclear Engineering and Design
JF - Nuclear Engineering and Design
M1 - 112749
ER -