Abstract
This study evaluated the performance characteristics of a molten carbonate fuel cell (MCFC) under sulfur poisoning condition. A 100 cm 2 bench-scale MCFC was used for the performance test. The performance of the cell at the normal operation condition was measured at 620 °C under atmospheric pressure. To evaluate the sulfur poisoning effect, 50 ppm H 2 S/Balanced N 2 gas mixture at a flow rate of 30 ml/min was injected into the anode. The cell performance was analyzed via steady-state polarization (SSP) and inert gas step addition (ISA) methods. The overpotential of the cell was observed to have been changed by the injection of H 2 S gas, and an overpotential increase of ca. 40% was recorded after about 100 hours from the point of addition of the H 2 S gas. A voltage reduction rate of −2.62×10 −4 mV/s was recorded at a current density of 150mA/cm 2 after about 240 hours. The steady-state polarization characteristics of the cell showed that the sulfur poisoning was relatively slow. In addition, the effect of H 2 S gas on the cell performance was quantitatively measured by the ISA method.
| Original language | English |
|---|---|
| Pages (from-to) | 600-604 |
| Number of pages | 5 |
| Journal | Korean Journal of Chemical Engineering |
| Volume | 36 |
| Issue number | 4 |
| DOIs | |
| State | Published - Apr 1 2019 |
| Externally published | Yes |
Keywords
- Anode
- Inert Gas Step Addition
- Molten Carbonate Fuel Cell
- Overpotential
- Sulphur Poisoning
Fingerprint
Dive into the research topics of 'Effect of sulfur on the cell performance in a molten carbonate fuel cell'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver