Direct assay of filter media following deox testing

  • B. R. Westphal
  • , R. P. Lind
  • , J. J. Giglio
  • , D. G. Cummings
  • , M. W. Huntley
  • , C. D. Morgan
  • , K. J. Bateman
  • , D. L. Wahlquist
  • , D. A. Seli

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

4 Scopus citations

Abstract

The direct assay of filter media by gamma spectrometry following DEOX testing has distinct advantages over analytical chemistry. Prior to using gamma spectrometry for the quantification of cesium (Cs137), a calibration must be established with known sources since gamma spectrometry yields relative results. Quantitative analytical chemistry, in particular ICP-MS, has been performed on the filter media for comparison to the gamma spectrometry data. The correlation of gamma spectrometry to ICP-MS data is presented to justify the continued use of gamma spectrometry for filter media.

Original languageEnglish
Title of host publicationGLOBAL 2007
Subtitle of host publicationAdvanced Nuclear Fuel Cycles and Systems
Pages605-609
Number of pages5
StatePublished - 2007
EventGLOBAL 2007: Advanced Nuclear Fuel Cycles and Systems - Boise, ID, United States
Duration: Sep 9 2007Sep 13 2007

Publication series

NameGLOBAL 2007: Advanced Nuclear Fuel Cycles and Systems

Conference

ConferenceGLOBAL 2007: Advanced Nuclear Fuel Cycles and Systems
Country/TerritoryUnited States
CityBoise, ID
Period09/9/0709/13/07

Fingerprint

Dive into the research topics of 'Direct assay of filter media following deox testing'. Together they form a unique fingerprint.

Cite this