Abstract
We characterized high-power lithium-ion cells in terms of performance and cycle- and calendar life at 45 °C. Among other parameters, we measured the C/25 capacity every 4 weeks during the test. Differentiation of the C/25 voltage versus capacity data with respect to capacity yielded dV/dQ curves. Analysis of Q0 dV/dQ curves has shown that capacity fade in high-power lithium-ion cells can be complex. From the analysis, the anode material in a significant fraction of the cells showed two types of capacity loss. The loss of accessible material tended to happen early in cell life, either during formation or during the first 4 weeks of testing. Most likely this was caused by a physical rather than chemical process. After 4 weeks, the principal cause of capacity loss was side reactions.
| Original language | English |
|---|---|
| Pages (from-to) | 304-313 |
| Number of pages | 10 |
| Journal | Journal of Power Sources |
| Volume | 139 |
| Issue number | 1-2 |
| DOIs | |
| State | Published - Jan 4 2005 |
Keywords
- Battery
- Differential voltage
- Lithium ion
- Reference electrode
Fingerprint
Dive into the research topics of 'Differential voltage analyses of high-power lithium-ion cells 2. Applications'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver