TY - JOUR
T1 - Development, Construction, and Operation of the Agile Non-nuclear Microreactor Experimental Test Bed (MAGNET) and Helium Component Test Facility (He-CTF)
AU - Morton, Terry J.
AU - McKellar, Michael
AU - Sabharwall, Piyush
AU - Jaison, Shaleena
N1 - Publisher Copyright:
© This material is published by permission of the Idaho National Laboratory, for the U.S. Department of Energy under Contract No. DE-AC07-05ID14517. The US Government retains for itself, and others acting on its behalf, a paid-up, non-exclusive, and irrevocable worldwide use in said article to reproduce, prepare derivative works, distribute copies to the public, and perform publicly and display publicly, by or on behalf of the Government.
PY - 2024/8/28
Y1 - 2024/8/28
N2 - Idaho National Laboratory and the National Reactor Innovation Center (NRIC) constructed the Microreactor Agile Non-nuclear Experimental Test bed (MAGNET) to reduce uncertainty and risk for microreactor developers, users, and regulators. Additional capabilities, dubbed the Helium Component Test Facility (He-CTF) were added after construction was finished to provide a heat exchanger testing capability. The He-CTF construction was funded by the NRIC. MAGNET will generate validation data for dynamic modeling and scaling, thus enabling demonstration and validation of microreactor systems, components, and auxiliary systems. MAGNET was designed primarily for steady-state and normal startup, shutdown, and ramp transients around typical air-Brayton-cycle parameters of 650°C and 22 bar at a differential temperature of 290°C across the reactor. Some accident conditions, such as heat pipe failures, were envisioned. The facility has a capacity of 250 kW and can use nitrogen (N2) or helium (He), with maximum mass flow rates of 938 g/s for N2 and 70 g/s for He.
AB - Idaho National Laboratory and the National Reactor Innovation Center (NRIC) constructed the Microreactor Agile Non-nuclear Experimental Test bed (MAGNET) to reduce uncertainty and risk for microreactor developers, users, and regulators. Additional capabilities, dubbed the Helium Component Test Facility (He-CTF) were added after construction was finished to provide a heat exchanger testing capability. The He-CTF construction was funded by the NRIC. MAGNET will generate validation data for dynamic modeling and scaling, thus enabling demonstration and validation of microreactor systems, components, and auxiliary systems. MAGNET was designed primarily for steady-state and normal startup, shutdown, and ramp transients around typical air-Brayton-cycle parameters of 650°C and 22 bar at a differential temperature of 290°C across the reactor. Some accident conditions, such as heat pipe failures, were envisioned. The facility has a capacity of 250 kW and can use nitrogen (N2) or helium (He), with maximum mass flow rates of 938 g/s for N2 and 70 g/s for He.
KW - He-CTF
KW - MAGNET
KW - microreactor
KW - Nonnuclear testing
UR - https://www.scopus.com/pages/publications/85202788875
UR - https://www.osti.gov/pages/biblio/2438401
U2 - 10.1080/00295639.2024.2384218
DO - 10.1080/00295639.2024.2384218
M3 - Review article
AN - SCOPUS:85202788875
SN - 0029-5639
SP - 1
EP - 11
JO - Nuclear Science and Engineering
JF - Nuclear Science and Engineering
ER -