T1 - Design and testing of a low-cost sensor and sampling platform for indoor air quality
AU - Tryner, Jessica
AU - Phillips, Mollie
AU - Quinn, Casey
AU - Neymark, Gabe
AU - Wilson, Ander
AU - Jathar, Shantanu H.
AU - Carter, Ellison
AU - Volckens, John
N1 - Funding Information:
This work was funded by the National Institute on Minority Health and Health Disparities ( NIMHD ) of the National Institutes of Health ( NIH ) under award number R43MD014915. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH. The NIH was not involved in study design; in the collection, analysis, or interpretation of data; in writing of this article; or in the decision to submit the article for publication. The authors thank Delphine Farmer and Tyson Berg of the Colorado State University Department of Chemistry for help with calibrating the NO x and O 3 reference monitors.
Funding Information:
This work was funded by the National Institute on Minority Health and Health Disparities (NIMHD) of the National Institutes of Health (NIH) under award number R43MD014915. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH. The NIH was not involved in study design; in the collection, analysis, or interpretation of data; in writing of this article; or in the decision to submit the article for publication. The authors thank Delphine Farmer and Tyson Berg of the Colorado State University Department of Chemistry for help with calibrating the NOx and O3 reference monitors.
Publisher Copyright:
© 2021 The Authors
PY - 2021/12
Y1 - 2021/12
N2 - Americans spend most of their time indoors at home, but comprehensive characterization of in-home air pollution is limited by the cost and size of reference-quality monitors. We assembled small “Home Health Boxes” (HHBs) to measure indoor PM2.5, PM10, CO2, CO, NO2, and O3 concentrations using filter samplers and low-cost sensors. Nine HHBs were collocated with reference monitors in the kitchen of an occupied home in Fort Collins, Colorado, USA for 168 h while wildfire smoke impacted local air quality. When HHB data were interpreted using gas sensor manufacturers' calibrations, HHBs and reference monitors (a) categorized the level of each gaseous pollutant similarly (as either low, elevated, or high relative to air quality standards) and (b) both indicated that gas cooking burners were the dominant source of CO and NO2 pollution; however, HHB and reference O3 data were not correlated. When HHB gas sensor data were interpreted using linear mixed calibration models derived via collocation with reference monitors, root-mean-square error decreased for CO2 (from 408 to 58 ppm), CO (645 to 572 ppb), NO2 (22 to 14 ppb), and O3 (21 to 7 ppb); additionally, correlation between HHB and reference O3 data improved (Pearson's r increased from 0.02 to 0.75). Mean 168-h PM2.5 and PM10 concentrations derived from nine filter samples were 19.4 μg m−3 (6.1% relative standard deviation [RSD]) and 40.1 μg m−3 (7.6% RSD). The 168-h PM2.5 concentration was overestimated by PMS5003 sensors (median sensor/filter ratio = 1.7) and underestimated slightly by SPS30 sensors (median sensor/filter ratio = 0.91).
AB - Americans spend most of their time indoors at home, but comprehensive characterization of in-home air pollution is limited by the cost and size of reference-quality monitors. We assembled small “Home Health Boxes” (HHBs) to measure indoor PM2.5, PM10, CO2, CO, NO2, and O3 concentrations using filter samplers and low-cost sensors. Nine HHBs were collocated with reference monitors in the kitchen of an occupied home in Fort Collins, Colorado, USA for 168 h while wildfire smoke impacted local air quality. When HHB data were interpreted using gas sensor manufacturers' calibrations, HHBs and reference monitors (a) categorized the level of each gaseous pollutant similarly (as either low, elevated, or high relative to air quality standards) and (b) both indicated that gas cooking burners were the dominant source of CO and NO2 pollution; however, HHB and reference O3 data were not correlated. When HHB gas sensor data were interpreted using linear mixed calibration models derived via collocation with reference monitors, root-mean-square error decreased for CO2 (from 408 to 58 ppm), CO (645 to 572 ppb), NO2 (22 to 14 ppb), and O3 (21 to 7 ppb); additionally, correlation between HHB and reference O3 data improved (Pearson's r increased from 0.02 to 0.75). Mean 168-h PM2.5 and PM10 concentrations derived from nine filter samples were 19.4 μg m−3 (6.1% relative standard deviation [RSD]) and 40.1 μg m−3 (7.6% RSD). The 168-h PM2.5 concentration was overestimated by PMS5003 sensors (median sensor/filter ratio = 1.7) and underestimated slightly by SPS30 sensors (median sensor/filter ratio = 0.91).
KW - Electrochemical gas sensors
KW - Gas cooking burners
KW - Nitrogen dioxide
KW - NO2
KW - Particulate matter
KW - Wildfire smoke
UR - https://www.scopus.com/pages/publications/85116821136
UR - https://www.mendeley.com/catalogue/453ebe88-86b7-3f31-a3f3-4404c8d7686c/
U2 - 10.1016/j.buildenv.2021.108398
DO - 10.1016/j.buildenv.2021.108398
M3 - Article
AN - SCOPUS:85116821136
SN - 0360-1323
VL - 206
JO - Building and Environment
JF - Building and Environment
M1 - 108398
ER -