TY - GEN
T1 - Chemical warfare agent identification by PGNAA
T2 - 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015
AU - Wharton, C. J.
AU - Seabury, E. H.
AU - Krebs, K. M.
AU - Caffrey, A. J.
N1 - Publisher Copyright:
© 2015 IEEE.
PY - 2016/10/3
Y1 - 2016/10/3
N2 - The PINS Chemical Assay System, developed by Idaho National Laboratory (INL) is a field-portable Prompt Gamma-ray Neutron Activation Analysis (PGNAA) system. [1] For over 20 years, the U.S. military has used the PINS to nondestructively identify the fill chemical inside thousands of suspect chemical warfare munitions. First- and second-generation PINS systems use a 252Cf neutron source to induce capture reactions and inelastic-scattering reactions in the object under test. Currently, we are testing two third-generation PINS systems, using neutron generators in lieu of a 252Cf radioisotopic source, to simplify PINS shipping and storage logistics. We present here a comparison of the spectra collected during a series of blind tests performed with actual chemical warfare agents, using all three neutron source types. To our knowledge, this is the first test directly comparing the gamma-ray response of live-chemical warfare agents to neutrons from a 252Cf source, a DD neutron generator, and a DT neutron generator.
AB - The PINS Chemical Assay System, developed by Idaho National Laboratory (INL) is a field-portable Prompt Gamma-ray Neutron Activation Analysis (PGNAA) system. [1] For over 20 years, the U.S. military has used the PINS to nondestructively identify the fill chemical inside thousands of suspect chemical warfare munitions. First- and second-generation PINS systems use a 252Cf neutron source to induce capture reactions and inelastic-scattering reactions in the object under test. Currently, we are testing two third-generation PINS systems, using neutron generators in lieu of a 252Cf radioisotopic source, to simplify PINS shipping and storage logistics. We present here a comparison of the spectra collected during a series of blind tests performed with actual chemical warfare agents, using all three neutron source types. To our knowledge, this is the first test directly comparing the gamma-ray response of live-chemical warfare agents to neutrons from a 252Cf source, a DD neutron generator, and a DT neutron generator.
UR - https://www.scopus.com/pages/publications/84994316248
U2 - 10.1109/NSSMIC.2015.7581754
DO - 10.1109/NSSMIC.2015.7581754
M3 - Conference contribution
AN - SCOPUS:84994316248
T3 - 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015
BT - 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015
PB - Institute of Electrical and Electronics Engineers Inc.
Y2 - 31 October 2015 through 7 November 2015
ER -