Skip to main navigation Skip to search Skip to main content

Characteristics of the stacked microstructured solid state neutron detector

  • S. L. Bellinger
  • , R. G. Fronk
  • , W. J. McNeil
  • , J. K. Shultis
  • , T. J. Sobering
  • , D. S. McGregor

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

15 Scopus citations

Abstract

Silicon diodes with large aspect ratio perforated microstructures backfilled with 6LiF show a dramatic increase in neutron detection efficiency beyond that of conventional thin-film coated planar devices. Described in this work are advancements in the technology with increased microstructure depths and detector stacking methods that work to increase thermal-neutron detection efficiency. Models for ion energy deposition and intrinsic thermal-neutron detection efficiency for the straight trench design are described and results presented. A dual stacked device was fabricated by coupling two detectors back-to-back, along with counting electronics, into a single detector. Experimentally verified results and modeled predictions are compared. The stacked device delivered 37% intrinsic thermal-neutron detection efficiency, lower than the predicted value of 47%. It was determined that this lower observed efficiency is due to detector misalignment in the stacked structure and ballistic deficit from slow charge collection from the deep trench structures. The intrinsic thermal-neutron detection efficiency depends strongly upon the geometry, size, and depth of the perforated microstructures. This work is part of on-going research to develop solid-state semiconductor neutron detectors with high detection efficiencies.

Original languageEnglish
Title of host publicationHard X-Ray, Gamma-Ray, and Neutron Detector Physics XII
DOIs
StatePublished - 2010
EventHard X-Ray, Gamma-Ray, and Neutron Detector Physics XII - San Diego, CA, United States
Duration: Aug 2 2010 → Aug 4 2010

Publication series

NameProceedings of SPIE - The International Society for Optical Engineering
Volume7805
ISSN (Print)0277-786X

Conference

ConferenceHard X-Ray, Gamma-Ray, and Neutron Detector Physics XII
Country/TerritoryUnited States
CitySan Diego, CA
Period08/2/10 → 08/4/10

Keywords

  • He-3 replacement technology
  • microstructured semiconductor diode
  • perforated detectors
  • solid state neutron detectors

Fingerprint

Dive into the research topics of 'Characteristics of the stacked microstructured solid state neutron detector'. Together they form a unique fingerprint.

Cite this