Skip to main navigation Skip to search Skip to main content

Carrier gas attenuation in gamma assay of radioactive xenon samples

  • Troy A. Robinson
  • , John P. Peterson
  • , Robert K. Hague

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Gamma attenuation attributable to xenon and carbon dioxide carrier gas in radioactive xenon assay samples has been calculated using Monte Carlo n-Particle (MCNP) transport code for the 0.65 mL flame sealed ampoule (bean), and 15 mL and 50 mL Schlenk tube geometries. The attenuation was correlated as a % loss per standard mL of carrier gas. High Purity Ge gamma spectroscopy experiments were performed to measure against the MCNP results. The experimental results from the 133Xe in xenon carrier gas in a bean geometry showed 0.97 ± 0.4% loss per standard mL xenon, which was in agreement with the MCNP predictions.

Original languageEnglish
Pages (from-to)3015-3023
Number of pages9
JournalJournal of Radioanalytical and Nuclear Chemistry
Volume331
Issue number7
Early online dateJun 20 2022
DOIs
StatePublished - Jul 1 2022

Keywords

  • Attenuation
  • CTBTO
  • Gamma assay
  • Nuclear explosion monitoring
  • Radioactive xenon

INL Publication Number

  • INL/JOU-21-65384
  • 105386

Fingerprint

Dive into the research topics of 'Carrier gas attenuation in gamma assay of radioactive xenon samples'. Together they form a unique fingerprint.

Cite this