Abstract
Monte Carlo calculations of pressure vessel (PV) neutron fluence have been performed to benchmark discrete ordinates (S N) transport methods. These calculations, along with measured data at the ex-vessel cavity dosimeter, provide a means to examine various uncertainties associated with the S N transport calculations. For the purpose of the PV fluence calculations, synthesized 3-D deterministic models are shown to produce results that are quite comparable to results from Monte Carlo methods, provided the two methods utilize the same multigroup cross section libraries. Differences between continuous energy Monte Carlo and multigroup S N calculations are analyzed and discussed.
| Original language | American English |
|---|---|
| Title of host publication | Int. Conf. on Mathematics and Computations, Reactor Physics, and Environmental Analysis, Portland, OR |
| State | Published - Apr 1995 |
Fingerprint
Dive into the research topics of 'Benchmarking of Synthesized 3-D Sn Transport Methods for Pressure Vessel Fluence Calculations with Monte Carlo'. Together they form a unique fingerprint.Cite this