A slow-ramp (0.1%/s), extended overpower (∼32%) transient was conducted in the Experimental Breeder Reactor-II (EBR-II) on 19 metallic alloy fuel elements, including both binary (U-Zr) and ternary (U-Pu-Zr) fuel designs. The elements were clad in either Type 316 SS or HT9. Before the transient, the elements were pre-irradiated under steady-state or steady-state plus duty-cycle (periodic 15% overpower transient) conditions in various EBR-II sub-assemblies and reached burnups ranging from ∼5 to ∼12 at%. The fuel pins were then consolidated into the X512 sub-assembly for the overpower transient. Cladding integrity was maintained for all fuel pins throughout the entirety of normal operation and the overpower transient test. Post-irradiation examination (PIE) demonstrated that mild restructuring was evident within the fuel phase. However, these changes were not significant enough to expect changes in irradiation performance under normal operating conditions if the fuel elements were returned to service. These results empirically validate that limits on sodium fast reactor operational transients (e.g. power ramps) could be applied with adequate safety margins to fuel failure or non-reversible damage.

Original languageEnglish
Article number153304
JournalJournal of Nuclear Materials
Volume557
Early online dateSep 20 2021
DOIs
StatePublished - Dec 15 2021

Keywords

  • EBR-II
  • Irradiation performance
  • Metallic fuel
  • Overpower transient

INL Publication Number

  • INL/JOU-20-60036
  • 53981

Fingerprint

Dive into the research topics of 'Behavior of metallic fast reactor fuels during an overpower transient'. Together they form a unique fingerprint.

Cite this