TY - GEN
T1 - Anomaly Detection and Identification Using a Leave-One-Variable-Out Method
AU - Farber, Jacob A.
AU - Al Rashdan, Ahmad Y.
AU - Reese, Randall
N1 - Funding Information:
Idaho National Laboratory is a multi-program laboratory operated by Battelle Energy Alliance, LLC for the U.S. Department of Energy under contract no. DE-AC07-05ID14517. This work of authorship was prepared as an account of work sponsored by an agency of the U.S. Government. Neither the U.S. Government, nor any agency thereof, nor any of their employees makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. The U.S. Government retains, and the publisher, by accepting the article for publication, acknowledges that the U.S. Government retains a nonexclusive, paid-up, irrevocable, worldwide license to publish or reproduce the published form of this manuscript, or allow others to do so, for U.S. Government purposes. The views and opinions of authors expressed herein do not necessarily state or reflect those of the U.S. Government or any agency thereof. The document number issued by Idaho National Laboratory for this paper is INL/CON-23-71470.
Funding Information:
The authors wish to thank the U.S. Department of Energy Light Water Reactor Sustainability (LWRS) program for funding this effort. They also wish to thank Florida Power and Light Company—which is part of NextEra Energy, Inc.—for collaborating on this effort.
Publisher Copyright:
© 2023 American Nuclear Society, Incorporated.
PY - 2023
Y1 - 2023
N2 - At nuclear power plants (NPPs), anomaly detection and identification (i.e., determining the causes of anomalies) are important tasks for ensuring the safe and efficient operation of NPPs. These tasks are currently labor-intensive and costly, and are made more difficult by the size and complexity of NPP systems. An alternative approach to conducting these tasks is to automate them, such as via the reconstruction-based contribution method, which is a well-researched unsupervised machine learning method that uses a data-driven model of anomaly-free behavior to detect events and then identify each variable’s contributions to those events. The present effort developed a novel contribution approach that utilized a leave-one-variable-out (LOVO) model, with which each variable is predicted using all the other variables. The novelty lay in transforming this model into a reconstruction model and modifying the identification algorithm to work with the new reconstruction model. To evaluate this method in a controlled environment, a synthetic dataset based on spring-mass-damper (SMD) systems (commonly found in mechanical engineering references) was used, with known anomalies introduced into the system. The proposed method successfully detected the anomalies and afforded insights into their causes, thus enabling the appropriate identifications to be made.
AB - At nuclear power plants (NPPs), anomaly detection and identification (i.e., determining the causes of anomalies) are important tasks for ensuring the safe and efficient operation of NPPs. These tasks are currently labor-intensive and costly, and are made more difficult by the size and complexity of NPP systems. An alternative approach to conducting these tasks is to automate them, such as via the reconstruction-based contribution method, which is a well-researched unsupervised machine learning method that uses a data-driven model of anomaly-free behavior to detect events and then identify each variable’s contributions to those events. The present effort developed a novel contribution approach that utilized a leave-one-variable-out (LOVO) model, with which each variable is predicted using all the other variables. The novelty lay in transforming this model into a reconstruction model and modifying the identification algorithm to work with the new reconstruction model. To evaluate this method in a controlled environment, a synthetic dataset based on spring-mass-damper (SMD) systems (commonly found in mechanical engineering references) was used, with known anomalies introduced into the system. The proposed method successfully detected the anomalies and afforded insights into their causes, thus enabling the appropriate identifications to be made.
KW - anomaly detection
KW - anomaly identification
KW - nuclear power
KW - root cause analysis
UR - https://www.scopus.com/pages/publications/85183319510
UR - https://www.mendeley.com/catalogue/22398ab6-f79f-3b98-b6f6-30ec333cd74e/
U2 - 10.13182/NPICHMIT23-41363
DO - 10.13182/NPICHMIT23-41363
M3 - Conference contribution
AN - SCOPUS:85183319510
T3 - Proceedings of 13th Nuclear Plant Instrumentation, Control and Human-Machine Interface Technologies, NPIC and HMIT 2023
SP - 441
EP - 446
BT - Proceedings of 13th Nuclear Plant Instrumentation, Control and Human-Machine Interface Technologies, NPIC and HMIT 2023
PB - American Nuclear Society
T2 - 13th Nuclear Plant Instrumentation, Control and Human-Machine Interface Technologies, NPIC and HMIT 2023
Y2 - 15 July 2023 through 20 July 2023
ER -