Abstract

Independent numerical simulations have been performed using the MCNP5 and SCALE5 radiation transport codes to evaluate the effectiveness of a concrete facility designed to shield personnel from neutron radiation emitted from DT neutron generators. The analysis considered radiation source terms of 14.1 MeV monoenergetic neutrons located at three discrete locations within the two test vaults in the facility, calculating neutron and photon dose rates at 44 locations around the facility using both codes. In addition, dose rate contours were established throughout the facility using the MCNP5 mesh tally feature. Neutron dose rates calculated outside of the facility are predicted to be below 0.01 mrem/h at all locations when all neutron generator source terms are operating within the facility. Similarly, the neutron dose rate in one empty test vault when the adjacent test vault is being utilized is also less then 0.01 mrem/h. For most calculation locations outside the facility the photon dose rates were less then the neutron dose rates by a factor of 10 or more.

Original languageEnglish
Pages (from-to)1125-1133
Number of pages9
JournalApplied Radiation and Isotopes
Volume65
Issue number10
DOIs
StatePublished - Oct 2007
Externally publishedYes

Keywords

  • DT neutron
  • Neutron generator
  • Shielding

Fingerprint

Dive into the research topics of 'Analysis of a shield design for a DT neutron generator test facility'. Together they form a unique fingerprint.

Cite this