Abstract
A new olivine-melt thermometer based on the partitioning of Ni ( DNiOl/liqNi with a form similar to the Beattie (1993) DDNiOl/liqMg thermometer, is presented in this study. It is calibrated on a data set of 123 olivine-melt equilibrium experiments from 16 studies in the literature that pass the following five filters: (1) 1 bar only, (2) analyzed totals between 99.0-101.0 wt% for olivine and 98.5-101.0 wt% for quenched glasses, (3) olivine is the only silicate phase in equilibrium with the melt, (4) the NiO concentration is ≥0.1 wt% in olivine and ≥0.01 wt% in quenched glass, and (5) no metallic phase is present other than the capsule. The final data set spans a wide range of temperatures (1170-1650 °C), liquid compositions (37-66 wt% SiO2; 4-40 wt% MgO; 107-11 087 ppm Ni), and olivine compositions (Fo36-100; 0.10-15.7 wt% NiO). The Ni-thermometer recovers the 123 experimental temperatures within ±29 °C (1σ), with an average residual of 0 °C. A re-fitted version of the Mg-thermometer of Beattie (1993), calibrated on the same 123 experiments as for the Ni-thermometer, results in an average residual of 1 ± 26 °C (1σ). When both thermometers are applied to the same 123 experiments, the average ΔT (TMg - TNi) is 1 ± 29 °C (1σ), which confirms that the Mg- and Ni-thermometers perform equally well over a wide range of anhydrous melt composition and temperature at 1 bar. The pressure dependence of the Ni-thermometer under crustal conditions (≤1 GPa) is shown to be negligible through comparison with experimental results from Matzen et al. (2013), whereas the pressure dependence of the Mg-thermometer is up to 52 °C at ≤1 GPa (Herzberg and O'Hara 2002). Therefore, neglecting the effect of pressure when applying both thermometers to basalts that crystallized olivine at crustal depths (≤1 GPa) is expected to lead to negative ΔT (TMg - TNi) values (≤ -52 °C). Application of the two thermometers to nine mid-ocean ridge basalts results in an average ΔT of -3°, consistent with shallow crystallization of olivine under nearly anhydrous conditions. In contrast, application of the two thermometers to 18 subduction-zone basalts leads to an average ΔT of +112°; this large positive ΔT value cannot be explained by the effect of pressure, temperature or anhydrous melt composition. It is well documented in the literature that DDNiOl/liqMg is affected by dissolved water in the melt and that Mg-thermometers overestimate the temperature of hydrous basalts if an H2O correction is not applied (e.g., Putirka et al. 2007). Therefore, the reason why hydrous arc basalts have higher ΔT (TMg - TNi) values than MORBs may be because DNiOl/liqNi is less sensitivite to water in the melt, which is supported by new Ni-partitioning results on three olivine-melt equilibrium experiments on a basaltic andesite with up to 5 wt% H2O. More hydrous experiments are needed to confirm that the Ni-thermometer can be applied to hydrous melts without a correction for H2O in the melt.
| Original language | English |
|---|---|
| Pages (from-to) | 750-765 |
| Number of pages | 16 |
| Journal | American Mineralogist |
| Volume | 102 |
| Issue number | 4 |
| DOIs | |
| State | Published - Apr 1 2017 |
Keywords
- HO
- Ni partitioning
- olivine
- subduction zone magma
- thermometry
Fingerprint
Dive into the research topics of 'A comparison of olivine-melt thermometers based on DMg and DNi: The effects of melt composition, temperature, and pressure with applications to MORBs and hydrous arc basalts'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver