Abstract
Two testing protocols, QC/T 743 and those used by the U.S. Advanced Battery Consortium (USABC), were compared using cells based on LiFePO4/graphite chemistry. Differences in the protocols directly affected the data and the performance decline mechanisms deduced from the data. In all cases, the rate of capacity fade was linear with time. Overall, the testing protocols produced very similar data when the testing conditions and metrics used to define performance were similar. The choice of depth of discharge and pulse width had a direct effect on the apparent rate of resistance increased and estimated cell life. At greater percent depth of discharge (%DOD) and pulse width, the estimated life was shorter that at lower %DOD and shorter pulse width. This indicates that cells which were at the end of life based on the USABC protocol were not at end of life based on the QC/T 743 protocol by a large margin.
| Original language | English |
|---|---|
| Pages (from-to) | 268-273 |
| Number of pages | 6 |
| Journal | Journal of Power Sources |
| Volume | 306 |
| DOIs | |
| State | Published - Feb 29 2016 |
Keywords
- Battery testing
- Lithium-ion batteries
- Test protocols
Fingerprint
Dive into the research topics of 'A comparison of battery testing protocols: Those used by the U.S. advanced battery consortium and those used in China'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver