A comparative study of thermosyphons used for freezing soil.

  • F. D. Haynes
  • , J. P. Zarling

Research output: Contribution to journal › Article › peer-review

2 Scopus citations

Abstract

Thermosyphons, both open and closed, and both single and two phase, are used in cold regions to remove heat from soil and ensure the integrity of foundations. A new application is proposed for use with marine structures to prevent uplifting of piles on ice-covered rivers and lakes subjected to water level changes. Results of a full scale field installation and laboratory tests are presented. The field test was conducted with a forced air open bayonet tube heat exchanger. Laboratory tests were conducted with a forced air bayonet tube heat exchanger, an ammonia filled two phase heat exchanger, and a CO SUB 2 filled two phase heat exchanger which is based on the test results. Performance characteristics for each heat exchanger are given and a comparison made of their heat removal effectiveness. (A)

Original languageEnglish
JournalAmerican Society of Mechanical Engineers (Paper)
StatePublished - 1982

Fingerprint

Dive into the research topics of 'A comparative study of thermosyphons used for freezing soil.'. Together they form a unique fingerprint.