TY - JOUR
T1 - 1-D array of perforated diode neutron detectors
AU - McNeil, Walter J.
AU - Bellinger, Steven L.
AU - Unruh, Troy C.
AU - Henderson, Chris M.
AU - Ugorowski, Phil
AU - Morris-Lee, Bryce
AU - Taylor, Russell D.
AU - McGregor, Douglas S.
N1 - Funding Information:
Dr. Ben Blalock and Dr. Chuck Britton along with their research group at the University of Tennessee, Knoxville, designed the ASIC that provides signal amplification and digital output for the diode array. Dr. Lowell Crowe and his team at Oak Ridge National Laboratory for providing a PC interface card to acquire data from the motherboard, and scheduled beam time at the HFIR. This work was supported by NSF IMR-MIP Grant no. 0412208, and DTRA contract DTRA-01-03-C-0051.
PY - 2009/6/1
Y1 - 2009/6/1
N2 - Performance of a 4 cm long 64-pixel perforated diode neutron detector array is compared with an identical array of thin-film coated diodes. The perforated neutron detector design has been adapted to a 1-D pixel array capable of 120 μm spatial resolution and counting efficiency greater than 12%. Deep vertical trenches filled with 6LiF provide outstanding improvement in efficiency over thin-film coated diode designs limited to only 4.5%. This work marks the final step towards the construction of a much larger array consisting of 1024 pixels spanning 10 cm. The larger detector array will be constructed with a sub-array of 64-pixel sensors, and will be used for small-angle neutron scattering experiments at the Spallation Neutron Source of Oak Ridge National Laboratory.
AB - Performance of a 4 cm long 64-pixel perforated diode neutron detector array is compared with an identical array of thin-film coated diodes. The perforated neutron detector design has been adapted to a 1-D pixel array capable of 120 μm spatial resolution and counting efficiency greater than 12%. Deep vertical trenches filled with 6LiF provide outstanding improvement in efficiency over thin-film coated diode designs limited to only 4.5%. This work marks the final step towards the construction of a much larger array consisting of 1024 pixels spanning 10 cm. The larger detector array will be constructed with a sub-array of 64-pixel sensors, and will be used for small-angle neutron scattering experiments at the Spallation Neutron Source of Oak Ridge National Laboratory.
KW - 3-D microstructured detector
KW - Neutron scattering detector
KW - Perforated diode
KW - Solid-state neutron detector
UR - https://www.scopus.com/pages/publications/65749096152
U2 - 10.1016/j.nima.2009.01.054
DO - 10.1016/j.nima.2009.01.054
M3 - Article
AN - SCOPUS:65749096152
SN - 0168-9002
VL - 604
SP - 127
EP - 129
JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
IS - 1-2
ER -